Oct 18, 2018 My Generator won’t Start Troubleshooting. If your generator won’t start, there could be any number of problems. I know that it can be infuriating if the power fails or you arrive at a campsite, just to find that your generator has just given up the ghost. The Honda EU3000is is part of the Generator test program at Consumer Reports. In our lab tests, Generator models like the EU3000is are rated on multiple criteria, such as. Sun Honda Remote Control Sun Honda Remote Control For Honda EU3000is User’s Guide The Sun remote control transmitter allows you to start and stop your generator from the leisure of your living space and gives you the flexibility to locate your generator where it will be out of sight and out of the way. 31ZT7610 00X31-ZT7-6100 o 2001-2006 Honda Motor Co., Ltd. Owner’s Manual GENERATOR EU3000is Black DIC F101 31ZT7610 00X31-ZT7-6100. START Return the key to. Honda EU3000iS inverter generator is a reliable source of power even for the most sensitive and delicate equipment such as computers. These items need clean and consistent source of power and you can be sure that Honda EU3000iS inverter generator will give you enough electric power. Honda's advanced inverter technology provides 3,000-Watt of extremely quiet and fuel-efficient power. The eu3000is can operate a wide variety of appliances, making it perfect for use at home or camping.
My Generator won’t Start, what’s wrong? This is a common problem that many generator owners eventually have. Let’s face it, for any product with an engine, eventually it won’t start. Whether it’s a chainsaw, a car or a portable generator — what do you do when your generator won’t start?
My Generator won’t Start Troubleshooting
If your generator won’t start, there could be any number of problems. I know that it can be infuriating if the power fails or you arrive at a campsite, just to find that your generator has just given up the ghost.
From many years of experience, I know that the problem is usually quite simple if you know what to look for. In this article, I’m going to look at the common reasons why your generator won’t start and some of the less common ones. If, after following this advice, your generator still won’t start, you might need to contact your dealership for help. Though, it’s very likely that you’ll find the cause and have your generator up and running in no time.
VIDEO How to Start Your Generator
Honda Eu3000is Generator Parts Diagram
Don’t Panic
The most common cause for a generator not starting is because of engine flooding. This means that unburned fuel has collected in the combustion chamber causing wet fuel to collect on the spark plug. If you continue to pull on the recoil starter or crank the electric starter too many times with no success, you’re just aggravating the problem.
Sometimes it’s a good idea to just wait 5-minutes and then try again.
First check that you’ve done everything correctly. The on switch must be in the correct position, otherwise there will be no spark. This may seem obvious, but you’ll be surprised how many people can forget this and then start to panic.
The fuel tap must be in the correct position and so must the choke if you’re performing a cold start. Of course, you must make sure there’s gas in the tank.
Make sure the power supply to your electrical outlets are switched off before starting your generator.
If you have a 4-stroke engine, it probably has a low oil shutoff switch – so check that the oil level is sufficient. For a 2-stroke engine, make sure you’ve mixed the oil and gas at the correct ratio.
If you’re sure that you’ve followed the correct starting procedures and your generator still won’t start, there may be a simple technical problem. Here’s how you go about addressing these generator starting issues.
VIDEO 3 things to check when your generator won’t start
Your Generator Needs Spark
If the on/off switch is in the correct position, you should have power to your spark plug, unless there’s a problem. Using a spark plug tester can simplify things. If you don’t have one, there’s a lot you can determine by a visual inspection.
Before you remove the spark plug, check the cord from the ignition coil to the spark plug. It often happens that a generator won’t start because the HT lead that conducts the current to the sparkplug has worked loose, or is damaged. If you disconnect this lead from the plug or coil, you should here a slight popping sound as you break the vacuum inside the connection. If you don’t, this means that the cord was not properly connected.
So remove the cord from either end and blow it clean to make sure there’s no debris inside that could interfere with the spark. At the same time, check for any obvious damage to the cord. If you observe any breaks or burns, replace it. After doing this try start your generator.
If your generator still won’t start, check the spark plug. Remove the spark plug and inspect it for any obvious damage. If the porcelain part is damaged, the spark plug won’t work. Carbon buildup is another common sparkplug problem. If the spark plug is black and sooty, use a small piece of sandpaper to clean the terminals.
Oil on the spark plug can also be a problem, but this is usually an indication of something more serious and your rings are probably damaged. Even then, you should be able to start your generator by removing the oil. To do this, dip the terminals in some gas and rub it off with a clean cloth. You may get the generator started by doing this, but you should get it to the dealership as soon as possible to address the root cause of the problem.
If you spark-plug is wet, but not full of oil, this means it has unburned fuel on it. You should dry the fuel by blowing onto the spark-plug (gas evaporates quickly) then replace the spark-plug.
Once you’ve checked all these elements and you still have no spark, it’s likely that your ignition coil is faulty. If this is the case, you’ll need to replace it. United offensive cd key generator.
If you’re sure that you’re getting a good spark at your spark-plug and your generator still won’t start, it’s time to move to the next obvious issue.
VIDEO More Tips for Starting your Portable Generator
Your Generator Needs Fuel and Air
It’s quite easy to check if fuel is reaching your carburetor, you just need to check that there’s fuel in the hose. If it’s not a clear plastic hose, you’ll need to remove the fuel hose from the carburetor and see if there’s a flow of fuel. Fuel lines can become blocked and may need to be flushed with clean gas to allow it flow to the carburetor. Sometimes it’s better to replace the fuel hose.
A dirty air filter can cause a generator not to start. A visual inspection should give you an idea as to whether you’re getting enough air into your carburetor. If you have any doubt, you can try starting the generator without an air filter. If it starts, you should clean or replace the air filter. Never run the generator without the air filter, this can damage your carburetor and possibly the engine itself. If you remove the air filter for testing purposes, switch the generator off immediately after establishing that it can start.
A dirty carburetor is another common problem. This will often happen if you’ve stored the generator for a long period without draining the fuel from it before storage. A carburetor may also become clogged or blocked because of a lack of correct service. Use carburetor cleaner to remove any debris.
VIDEO Is It Your Low-Oil Engine Sensor? Troubleshooting Help
Electrical Malfunction
Modern generators have a few electrical components that could fail. You need to check that the on/off switch and low oil protection switch are function properly by using a multi-meter to check for continuity. Faulty switches should be replaced. Attempting to “bridge” a faulty switch is not a good idea.
You may also have a bad connection to your electric starter and you should be able to diagnose this with a visual inspection. If you’re going to replace electric wiring, make sure that you use the correct gauge – it must match the thickness of the wire that you’re replacing.
Recoil Starters
When you pull on your recoil starter, you should feel the resistance of the engine as you try start the generator. If the recoil rope is slack, it may not be engaging the flywheel and will need to be replaced.
Prevention is better than cure
Most of the generator starting problems that I’ve listed can be avoided with the correct care and maintenance. You should have your generator serviced by an authorized agent according to the maintenance schedule in your owner’s manual.
If you choose to service your generator yourself always use the specified grade oil in the engine and the correct filters.
Do regular visual inspections of your generator. Replacing frayed or damaged pipes and electrical wires before they become a problem will save you a lot of hassle.
Before storing your generator for periods of 3-months or longer, drain the fuel from the carburetor and empty the gas tank. To drain the carburetor, you simply switch the fuel tap to the off position while the engine is running. It will continue for a while and then engine will die from fuel starvation. This means there is no residual fuel in carburetor than can cause a blockage later.
Now you know what to do if your generator won’t start…
Hopefully, after reading this article, and watching the videos you’ll no longer be asking the question : “My generator won’t start, what do I do?” My hope is that you’ll be the portable generator starting expert in your circle of friends. Learning how to start a generator that simply won’t start is valuable to know, especially during an emergency when having an operational generator is an absolute must.
There are several types of generators. All these kinds of generators will depend on the power outsource that it can give to the user. Honda EU3000iS has several wattage selections that the user can select and here are some of them – 2000, 2500, 4000, 5000 watts and up. Improvements were also added to make it more pleasant and attractive to buyers like putting tube exhaustion, limiting the noise it produces and being more convenient when it comes to starting the machine. They can also use these generators for their homes and work and extra outdoor activities like when having camping.
Why do you need Honda EU3000iS Generator?
Generators are needed by people with businesses that are dependent on electricity. During electric interruptions, they can simply change their power supply to generators, thus will help them in continuing their business tractions with their clients. Honda EU3000iS included numerous features to provide quality and efficiency to users. They included wheels under the item for easy transportation and a backup starter power in case the other starter power supply is not functioning well. They also extended the length of hours of using the unit so that it will last for a longer period of time. It can run for around 20 hours with a fuel of 3.4 gallons.
Adding these features and modifications will absolutely attract buyers and this is what they would like to happen. The Honda EU3000iS has a DC outlet for charging a 12 volt automotive type battery. It is also accompanied by a three-year warranty for commercial and residential uses. Honda EU3000iS inverter generator is a reliable source of power even for the most sensitive and delicate equipment such as computers. These items need clean and consistent source of power and you can be sure that Honda EU3000iS inverter generator will give you enough electric power. It produces a stable and clean source of power in a portable package. This Honda inverter generator technology ensures users that you are getting the same electric power supply from those outlets that you have in your home. The Honda EU3000iS inverter generator 2600 watts can be used to provide a source of power to fragile equipment. Although its wattage is lower than other models out there, it has a smooth and nice sine wave as if it is from your home power supply. This generator will allow any of your digitally controlled units to run smoothly and properly.
Honda Generator Eu3000is Troubleshooting Key Wont Start Problems
Check out the Honda EU3000iS
Click below to watch the Honda EU3000iS in action.
Acquiring this unit is not a loss of money because it is really worth its amount. One of the advantages of this unit is that you can change the oil easily. It is protected by an oil alert system, notifying you if you need to add engine oil to the unit. It has a circuit protection and this will prevent the unit from overloading. It runs on regular gasoline, but if you put premium gasoline, it can still run smoothly and faultlessly. This Honda 3000iS generator is weather resistant, has 120 volts and smooth sine wave, equipped with a four stroke gas engine and will not disturb your sleeping time as it is very quiet with its Eco setting. If the batteries become dead, the pull start really works properly.
Honda Generator Eu3000is Troubleshooting Key Wont Start 2017
Read more: Honda Generator EU3000is Silver Cover
Honda Generator Eu3000is Troubleshooting Key Won't Start On Iphone
However, the unit still has some flaws that you have to deal with. One of these is that it is quite hard to start the unit if the temperature is cold. Honda EU3000iS offers a wider diversity of transfer switches with different sizes and style. You will also be given a cover to protect the item from water and other circumstances that will destroy the machine. There are Honda generators that have a folding lightweight halogen light and this is designed for EU2000 and EU1000.
Honda Generator Eu3000is Troubleshooting Key Wont Start Parts
Aside from that, you can use the battery tenders in keeping your generators always in top condition. If you need more power, you can use two Honda EU3000iS generators. This is one of the benefits that you can get from these items and you will be provided with a special cable, probably a kit to link two EU1000, EU2000 and EU3000. You can do this only for two identical or similar units. You can now get double power supply without purchasing a bigger and heavier generator, thus increasing your power supply without sacrificing portability. The Honda EU3000iS produces a lesser amount of noise than the traditional generator model. Thus, you don’t have to worry about angry neighbors being disturbed by your generator. The eco-throttle will reduce the sound level of the generator because it compresses the engine to not run in full speed. Thus, it will give no worries when you are using it because of the fact that you are not disturbing your neighbors. If you are looking for the best generator out there, you can surely rely on the Honda EU3000iS generator. It works quietly, provides enough power supply and is offered at a reasonable price.